¡Nos endieciochamos! Solo por HOY, ENVÍO GRATIS sobre $18.000  Ver más

Enviar a
Santiago, Región Metropolitana
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Smoke Component Yields from Bench-scale Fire Tests: 3. ISO 5660-1 / ASTM E 1354 with Enclosure and Variable Oxygen Concentration (en Inglés)
Formato
Libro Físico
Autor
Editorial
Idioma
Inglés
N° páginas
54
Encuadernación
Tapa Blanda
Dimensiones
28x21.6x0.3 cm
Peso
0.15 kg.
ISBN13
9781496019530

Smoke Component Yields from Bench-scale Fire Tests: 3. ISO 5660-1 / ASTM E 1354 with Enclosure and Variable Oxygen Concentration (en Inglés)

Nist (Autor) · Createspace · Tapa Blanda

Smoke Component Yields from Bench-scale Fire Tests: 3. ISO 5660-1 / ASTM E 1354 with Enclosure and Variable Oxygen Concentration (en Inglés) - Nist

Libro Nuevo Importado
Envío: 16 a 21 días háb.
$ 44.920$ 26.950
-40%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan más de 100 unidades

$ 26.950
Llega entre el 14 Oct y el 21 Oct a Santiago, Región Metropolitana. Seleccionar ubicación

Reseña del libro "Smoke Component Yields from Bench-scale Fire Tests: 3. ISO 5660-1 / ASTM E 1354 with Enclosure and Variable Oxygen Concentration (en Inglés)"

A standard procedure is needed for obtaining smoke toxic potency data for use in fire hazard and risk analyses. Room fire testing of finished products is impractical, directing attention to the use of apparatus that can obtain the needed data quickly and at affordable cost. This report presents examination of the fourth of a series bench-scale fire tests to produce data on the yields of toxic products in both pre-flashover and post-flashover flaming fires. The apparatus is the ISO 5660-1 / ASTM E 1354 cone calorimeter, modified to have an enclosure and a gas delivery system allowing variable oxygen concentration. The test specimens was cut from finished products that were also burned in room-scale tests: a sofa made of upholstered cushions on a steel frame, particleboard bookcases with a laminated finish, and household electric cable. Initially, the standard test procedure was followed. Subsequent variation in the procedure included reducing the supplied oxygen volume fraction to 0.18, 0.16, and 0.14, reducing the incident heat flux to 25 kW/m2, and reducing the gas flow rate by half. The yields of CO2 CO, HCl, and HCN were determined. The yields of other toxicants (NO, NO2, formaldehyde, and acrolein) were below the detection limits, but volume fractions at the detection limits were shown to be of limited toxicological importance relative to the detected toxicants. In general, performing the tests at the reduced oxygen volume fraction led to small increases on the toxic gas yields. The exceptions were an increase in the CO yield for the bookcase at 0.14 oxygen volume fraction. Reducing the incident heat flux had little effect on the toxic gas yields, other than increasing variability. Reducing the gas flow rate reduced the limits of detection by half, but also resulted in reduced gas yields at lower oxygen volume fractions. In none of the procedure variations did the CO yield approach the value of 0.2 found in real-scale post flashover fire tests.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes